Trailer provides mobile power distribution, fresh air ventilation, heated air, and compressed air systems for underground utility work.

Blower:
- Two-speed blower assembly.
- Ventilation: Up to 518 CFM on low speed to 888 CFM on high speed
- Heating: Both hot water heat exchanger and electric heat boost elements.
- Attached flexible 8 inch diameter blower hose with storage compartment.
|
24,000 BTU Air Conditioning Unit. A 60,000 BTU air conditioning unit is also available.

Exhaust manifold hot water heat exchanger
|
Pneumatics:
Both Oil-type compressor or Oil-free type compressor available.
Tool Air System:
- Pressure regulator and gauge.
- Design for minimum of 5.2 CFM at 100 psi.
- Adjustable air stream oil lubricator.
- 25 ft. x 1/4 inch hose reel with quick connect fitting.
|
 |
Dry Air System:
- Less than 10% humidity.
- Pressure regulator and gauge.
- Automatic moisture filter.
- Heatless, self-generating desiccant type air dryer.
- Solid-state humidity bypass and audible alarm circuit.
- 25 ft. x 1/4 inch hose reel with quick connect fitting.
|